Low-Temperature Sterilization
The ES-1400 has two different configurations of chamber door. The double-door model enables the Central Sterile Supply Department to use a pass-through system.
ES-1400 also has been updated with an improved user interface for better visibility.
Productive 142L Rectangular Chamber
The ES-1400 has significant 142-litre square chamber that maximizes the load capacity; it can hold a full-size container and large trays. It also comes with four sliding racks which enable the operator to optimize the load volume per cycle.
Hands-free door opening/ closing
- Automatic Door with Foot Sensor
- Opens / closes the chamber door without using the hands.
Full Colour Touch Panel Screen
Simple touch panel operations are available at a touch of your finger. The colour LCD screen uses large text for good visibility. A red screen and alarm will alert operators if any error occurs.
VIEW PORT and LED lighting make the interior visible
Thanks to PLASMA-FREE technology, the ES series features a VIEW PORT for observing loads inside the chamber while the chamber door is closed.
The interior of the sterilization chamber is lit with a white LED lamp, which allows operators to find out at a glance how the items are laid out and spot any items that may have been missed.
Normal and Short Cycle
NORMAL | SHORT | |
---|---|---|
approx.
50 minFor single and dual channel Rigid and semi-rigid endoscopes |
approx.
50 minFor single and dual channel flexible endoscopes |
approx.
28 minFor instruments and medical devices with no lumens or cavities |
Pass-through System
The double-door model enables the Central Sterile Supply Department to use a pass-through system.
In-wall Recessed Mounting System
The double-door model has an optional attachment for an in-wall recessed mounting system between contaminated/ decontaminated areas.
Specifications
Product Name | Hydrogen Peroxide Gas Sterilizer ES-1400 | |
---|---|---|
Chamber Capacity | 142L | |
Process Time (cycle) | Normal Cycle |
Approx. 50 Minutes |
Short Cycle | Approx. 28 Minutes | |
Door Type | Automatic Swing-down Door Double or Single Door |
|
Cycle Mode | Standard, Soft, Short | |
Sterilization Temperature | 55°C | |
Display | Full Colour LCD Touch Screen | |
Printing / Recording | Line Thermal Printer / SD Card | |
Power Requirement | 3-phase 208 V/380 V/400 V/415 V 50/60 Hz 3kW | |
Required Space (mm)* | Left: +50, Right: + 150, Back: +50, Top: +500 | |
Operational Environment Temperature/ Humidity |
10°C to 40°C / 50°F to 104°F 30-85% RH |
|
External Dimensions (mm) | 1710(H) x 925(D) x 750(W) | |
Weight | Approx. 410 kg |